beautypg.com

Sa-1100 boundary-scan interface timing -9 – Intel STRONGARM SA-1100 User Manual

Page 369

background image

SA-1100 Developer’s Manual

16-9

Boundary-Scan Test Interface

Table 16-1

shows the SA-1100 boundary-scan interface timing specifications.

Table 16-1.

SA-1100 Boundary-Scan Interface Timing

Symbol

Parameter

Minimum

Typical

Maximum

Units

Notes

Tbscl

TCK low period

50

ns

8

Tbsch

TCK high period

50

ns

8

Tbsis

TDI,TMS setup to [TCr]

10

ns

Tbsih

TDI,TMS hold from [TCr]

10

ns

Tbsoh

TDO hold time

5

ns

1

Tbsod TCf

to

TDO valid

40

ns

1

Tbsss

I/O signal setup to [TCr]

5

ns

4

Tbssh

I/O signal hold from
[TCr]

20 –

ns

4

Tbsdh

Data output hold time

5

ns

5

Tbsdd

TCf to data output valid

40

ns

Tbsoe

TDO enable time

5

ns

1,2

Tbsoz

TDO disable time

40

ns

1,3

Tbsde

Data output enable time

5

ns

5,6

Tbsdz

Data output disable time

40

ns

5,7

Tbsr

Reset period

30

ns

Tbsrs

TMS setup to [TRr]

10

ns

8

Tbsrh

TMS hold from [TRr]

10

ns

8

NOTES:

1. Assumes a 25-pF load on TDO. Output timing derates at 0.072 ns/pF of extra load applied.
2. TDO enable time applies when the TAP controller enters the Shift-DR or Shift-IR states.
3. TDO disable time applies when the TAP controller leaves the Shift-DR or Shift-IR states.
4. For correct data latching, the I/O signals (from the core and the pads) must be set up and held with respect

to the rising edge of TCK in the CAPTURE-DR state of the SAMPLE/PRELOAD and EXTEST instructions.

5. Assumes that the data outputs are loaded with the ac test loads.
6. Data output enable time applies when the boundary-scan logic is used to enable the output drivers.
7. Data output disable time applies when the boundary scan is used to disable the output drivers.
8. TCK may be stopped indefinitely in either the low or high phase.