Efficient Networks Siemens Sinamics S120 User Manual
Page 540

Appendix
A.2 Availability of SW functions
Drive Functions
540
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
No.
SW function
available
since FW
Servo
Vector
HW component
9
Edge modulation (higher output voltages) in the vector
control type, also with booksize devices
2.5
-
x
only for DAC Motor
Modules
(6SL3xxx-xxxxx-
0AA3)
10 DC braking
2.5 SP1
x
x
11 Armature short-circuit: Internal
2.5 SP1
x
x
12 Armature short-circuit: Intermittent voltage protection
2.5
x
-
only for DAC Motor
Modules
(6SL3xxx-xxxxx-
0AA3)
13 Automatic firmware update for DRIVE-CLiQ components
2.5
x
x
14 Save STARTER project direct to CF card
2.5
x
x
15 The terminal area for booksize infeeds (BLM, SLM, ALM)
can be parameterized to 230 V 3 AC
2.5 SP1
x
x
only for booksize
DAC infeeds
(6SL3xxx-xxxxx-
0AA3)
16 Automatic speed controller setting
2.5
x
since
FW2.1
17 Technological pump functions
2.5
-
x
18 Simultaneous cyclical operation of PROFIBUS and
PROFINET on CU320
2.5 SP1
x
x
19 Automatic restart also with servo
2.5 SP1
x
since
FW2.2
20 Operates at 500 μs PROFINET I/O
2.5 SP1
x
-
21 Absolute position information (X_IST2) with resolver
2.5
x
x
22 DC link voltage monitoring depending on the line voltage
2.5
x
x
23 Automatic line frequency detection
2.5
x
x
24 Acceleration signal at the ramp function generator output
2.5
x
x
25 Reset the drive device via parameter (p0972)
2.5
x
x
26 Alteration of the basic sampling time during the automatic
readjustment of the sampling times depending on the
number of drives on CU320 with vector (from 400 µs to
500 µs)
2.5
-
x
27 Dynamic energy management, extension of the Vdc_min,
Vdc_max control
2.5
x
x
28 Endless trace
2.5
x
x
29 Extended PROFIBUS monitoring with timer and binector
2.5
x
x
30 Indexed actual value acquisition
Simultaneous evaluation of multiple encoders
2.5 SP1
x
x