Communication PROFIBUS DP/PROFINET IO
10.1 Communications according to PROFIdrive
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
397
Error
value
Meaning
Comment
Additional
info
0x15
Response too long
The length of the present response exceeds the maximum
transfer length.
–
0x16
Illegal parameter address
Impermissible or unsupported value for attribute, number
of elements, parameter number, subindex or a
combination of these.
–
0x17
Illegal format
Write request: illegal or unsupported parameter data
format
–
0x18
No. of values inconsistent
Write request: a mismatch exists between the number of
values in the parameter data and the number of elements
in the parameter address.
–
0x19
Drive object does not exist
You have attempted to access a drive object that does not
exist.
–
0x65
Presently deactivated.
You have tried to access a parameter that, although
available, is currently inactive (e.g. n control set and
access to parameter from V/f control).
–
0x6B
Parameter %s [%s]: no write access
for the enabled controller
–
–
0x6C
Parameter %s [%s]: unit unknown
–
–
0x6D
Parameter %s [%s]: Write access
only in the commissioning state,
encoder (p0010 = 4).
–
–
0x6E
Parameter %s [%s]: Write access
only in the commissioning state,
motor (p0010 = 3).
–
–
0x6F
Parameter %s [%s]: Write access
only in the commissioning state,
power unit (p0010 = 2).
–
–
0x70
Parameter %s [%s]: Write access
only in the quick commissioning
mode (p0010 = 1).
–
–
0x71
Parameter %s [%s]: Write access
only in the ready mode (p0010 = 0).
–
–
0x72
Parameter %s [%s]: Write access
only in the commissioning state,
parameter reset (p0010 = 30).
–
–
0x73
Parameter %s [%s]: Write access
only in the commissioning state,
Safety (p0010 = 95).
–
–
0x74
Parameter %s [%s]: Write access
only in the commissioning state, tech.
application/units (p0010 = 5).
–
–
0x75
Parameter %s [%s]: Write access
only in the commissioning state
(p0010 not equal to 0).
–
–
0x76
Parameter %s [%s]: Write access
only in the commissioning state,
download (p0010 = 29).
–
–
0x77
Parameter %s [%s] may not be
written in download.
–
–