Temperature protection can be implemented using a temperature sensor (KTY/PTC). In
order to achieve a high torque accuracy, we recommend that a KTY temperature sensor is
used.
Table 4-5
Motor data
Parameter
Description
Remark
p0304
Rated motor voltage
If this value is not known, a "0" can also be
entered. Using this value, the stator leakage
inductance can be more precisely calculated
(p0356, p0357).
p0305
Rated motor current
-
p0307
Rated motor power
-
p0310
Rated motor frequency
-
p0311
Rated motor speed
-
If the torque constant k
T
is not stamped on the rating plate or specified in the data sheet, you
can calculate this value from the rated motor data or from the stall current I
o
and stall torque
M
o
as follows:
Q
QRP
0RWQRP
3
,
0RWQRP
PLQ
N7
QRP
V
ຘ
ຘ
ຘ
˭
Table 4-6
Optional data
Parameter
Description
Remark
p0314
Motor pole pair number
-
p0316
Motor torque constant
-
p0320
Motor rated magnetization
current/short-circuit current
This is used for the field weakening
characteristic
p0322
Maximum motor speed
Maximum mechanical speed
p0323
Maximum motor current
De-magnetization protection
p0325
Motor pole position information
-
p0327
Optimum motor load angle
-
p0328
PE spindle, reluctance torque
constant
-
p0329
Motor pole position identification
current
-
P0341
Motor moment of inertia
For speed controller pre-control
p0342
Ratio between the total
motor moment of inertia
-