5 braking module, 1 "braking module" function module, Features – Efficient Networks Siemens Sinamics S120 User Manual
Page 231: Description

Function modules
7.5 Braking Module
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
231
7.5
Braking Module
7.5.1
"Braking Module" function module
Features
● Braking the motor without any possibility of regenerating into the line supply (e.g. power
failure)
● Fast DC link discharge (booksize design)
● The Braking Module terminals are controlled via the drive object infeed (booksize and
chassis designs)
● Controlling up to 8 Braking Modules in a parallel circuit configuration
● Acknowledging faults at the Braking Module
Description
The "Braking Module" function module can be activated in the infeed drive object. The
appropriate binectors must be interconnected via digital inputs/outputs (e.g.: Control Unit,
TM31 or TB30) with the Braking Module.
In order to obtain the maximum power of a Braking Module, the Vdc_max control must be
disabled.
&RQWURO8QLW
;
U
%,%UDNLQJ0RGXOHIDXOW
S>@
$FWLYH6PDUW
%DVLF,QIHHG
;
U
%2%UDNLQJ0RGXOH
'LVDEOHIDXOWDFNQRZOHGJH
PHQW
S
;
U
%2%UDNLQJ0RGXOH
'&OLQNUDSLGGLVFKDUJH
S
;
U
S
;
U
S
%UDNLQJ0RGXOH
;
;
'2SUHZDUQLQJ
, WVKXWGRZQ
'2IDXOWEUDNLQJ
0RGXOHGLVDEOHG
;
;
',%UDNLQJ0RGXOH
GLVDEOHIDXOWDFNQRZO
HGJHPHQW
','&OLQN
)DVWGLVFKDUJLQJ
;
U
%,%UDNLQJ0RGXOH
3UHZDUQLQJIRU, WVKXWGRZQ
S>@
;
U
S>@
;
U
S>@
%UDNLQJ
Figure 7-5
Example of controlling two Booksize Braking Modules