beautypg.com

5 braking module, 1 "braking module" function module, Features – Efficient Networks Siemens Sinamics S120 User Manual

Page 231: Description

background image

Function modules

7.5 Braking Module

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

231

7.5

Braking Module

7.5.1

"Braking Module" function module

Features

● Braking the motor without any possibility of regenerating into the line supply (e.g. power

failure)

● Fast DC link discharge (booksize design)
● The Braking Module terminals are controlled via the drive object infeed (booksize and

chassis designs)

● Controlling up to 8 Braking Modules in a parallel circuit configuration
● Acknowledging faults at the Braking Module

Description

The "Braking Module" function module can be activated in the infeed drive object. The

appropriate binectors must be interconnected via digital inputs/outputs (e.g.: Control Unit,

TM31 or TB30) with the Braking Module.
In order to obtain the maximum power of a Braking Module, the Vdc_max control must be

disabled.

&RQWURO8QLW

;

U

%,%UDNLQJ0RGXOHIDXOW

S>@

$FWLYH6PDUW

%DVLF,QIHHG

;

U

%2%UDNLQJ0RGXOH

'LVDEOHIDXOWDFNQRZOHGJH

PHQW

S

;

U

%2%UDNLQJ0RGXOH

'&OLQNUDSLGGLVFKDUJH

S

;

U

S

;

U

S

%UDNLQJ0RGXOH

;

;

'2SUHZDUQLQJ

, WVKXWGRZQ

'2IDXOWEUDNLQJ

0RGXOHGLVDEOHG

;

;

',%UDNLQJ0RGXOH

GLVDEOHIDXOWDFNQRZO

HGJHPHQW

','&OLQN

)DVWGLVFKDUJLQJ

;

U

%,%UDNLQJ0RGXOH

3UHZDUQLQJIRU, WVKXWGRZQ

S>@

;

U

S>@

;

U

S>@

%UDNLQJ

Figure 7-5

Example of controlling two Booksize Braking Modules