beautypg.com

2 displays and using the bop20 – Efficient Networks Siemens Sinamics S120 User Manual

Page 493

background image

Basic information about the drive system

12.6 Parameterizing using the BOP20 (Basic Operator Panel 20)

Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4

493

● p0009 Device commissioning, parameter filter
● p0011 BOP password input (p0013)
● p0012 BOP password confirmation (p0013)
● r0019 CO/BO: Control word, BOP
● p0977 Save all parameters

Other drive objects (e.g. SERVO, VEKTOR, INFEED, TM41 etc.)

● p0010 Commissioning parameter filter

12.6.2

Displays and using the BOP20

Features

● Operating display
● Changing the active drive object
● Displaying/changing parameters
● Displaying/acknowledging faults and alarms
● Controlling the drive using the BOP20

Operating display

The operating display for each drive object can be set using p0005 and p0006. Using the

operating display, you can change into the parameter display or to another drive object. The

following functions are possible:
● Changing the active drive object

– Press key "FN" and "Arrow up" -> the drive object number at the top left flashes
– Select the required drive object using the arrow keys
– Acknowledge using the "P" key

● Parameter display

– Press the "P" key.
– The required parameters can be selected using the arrow keys.
– Press the "FN" key -> parameter r0000 is displayed
– Press the "P" key -> changes back to the operating display