5 control units without infeed control, 1 description – Efficient Networks Siemens Sinamics S120 User Manual
Page 463

Applications
11.5 Control Units without infeed control
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
463
11.4.6
Overview of key parameters (see SINAMICS S List Manual)
● p0105 Activate/deactivate drive object
● r0106 Drive object active/inactive
● p0897 BI: Parking axis selection
● r0896.0 BO: Parking axis status word
● p0151 DRIVE-CLiQ Hub component number
● p0154 DRIVE-CLiQ Hub identification using LED
● p0157 DRIVE-CLiQ Hub EPROM data version
● r0158 DRIVE-CLiQ Hub firmware version
11.5
Control Units without infeed control
11.5.1
Description
Description
To ensure that the drive line-up functions satisfactorily, you must ensure – among other
things – that the drives only draw power from the DC link when the infeed is in operation. In a
DC link line-up that is controlled by just one Control Unit and in which a drive object has an
infeed, the BICO interconnection p0864 = p0863.0 is established automatically during
commissioning.
In the following cases, the BICO input p0864 must be supplied manually:
● Smart Line Modules without DRIVE-CLiQ (5 kW and 10 kW)
● DC link line-up with more than one Control Unit