Efficient Networks Siemens Sinamics S120 User Manual
Page 492

Basic information about the drive system
12.6 Parameterizing using the BOP20 (Basic Operator Panel 20)
Drive Functions
492
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
BOP20 functions
Table 12-9 Functions
Name
Description
Backlighting
The backlighting can be set using p0007 in such a way that it switches itself off automatically
after the set time if no actions are carried out.
Changeover active drive
From the BOP perspective the active drive is defined using p0008 or using the keys "FN" and
"Arrow up".
Units
The units are not displayed on the BOP.
Access level
The access level for the BOP is defined using p0003.
The higher the access level, the more parameters can be selected using the BOP.
Parameter filter
Using the parameter filter in p0004, the available parameters can be filtered corresponding to
their particular function.
Selecting the operating
display
Actual values and setpoints are displayed on the operating display.
The operating display can be set using p0006.
User parameter list
Using the user parameter list in p0013, parameters can be selected for access.
Unplug while voltage is
present
The BOP can be withdrawn and inserted under voltage.
•
The ON and OFF keys have a function.
When withdrawing, the drives are stopped.
Once the BOP has been inserted, the drives must be switched on again.
.
•
ON and OFF keys have no function
Withdrawing and inserting has no effect on the drives.
Actuating keys
The following applies to the "P" and "FN" keys:
•
When used in a combination with another key, "P" or "FN" must be pressed first and then
the other key.
Parameters for BOP
All drive objects
● p0005 BOP operating display selection
● p0006 BOP operating display mode
● p0013 BOP user-defined list
● p0971 Drive object, save parameters
Drive object, Control Unit
● r0000 BOP operating display
● p0003 BOP access level
● p0004 BOP display filter
● p0007 BOP background lighting
● p0008 BOP drive object selection