2
Int16
Logic_Level_1_Gates_Active (M6)
Actuation Status of Level 1 Gates
0 … 65535
Bit 0
Level1_Gate1_Output
1 Indicates gate logic output is true
0 or 1
Bit 1
Level1_Gate2_Output
1 Indicates gate logic output is true
0 or 1
Bit 2
Level1_Gate3_Output
1 Indicates gate logic output is true
0 or 1
Bit 3
Level1_Gate4_Output
1 Indicates gate logic output is true
0 or 1
Bit 4
Level1_Gate5_Output
1 Indicates gate logic output is true
0 or 1
Bit 5
Level1_Gate6_Output
1 Indicates gate logic output is true
0 or 1
Bit 6
Level1_Gate7_Output
1 Indicates gate logic output is true
0 or 1
Bit 7
Level1_Gate8_Output
1 Indicates gate logic output is true
0 or 1
Bit 8
Level1_Gate9_Output
1 Indicates gate logic output is true
0 or 1
Bit 9
Level1_Gate10_Output
1 Indicates gate logic output is true
0 or 1
Bit 10 … 15
Reserved
Future Use
0
3
Int16
Metering_Status
Metering Conditions Status
0…65,535
Bit 0
Virtual_Wiring_Correction
1 = Virtual Wiring Correction ON
0…1
Bit 1
Voltage_Phase_V1
1 = Loss of V1 metering voltage
0…1
Bit 2
Voltage_Phase_V2
1 = Loss of V2 metering voltage
0…1
Bit 3
Voltage_Phase_V3
1 = Loss of V3 metering voltage
0…1
Bit 4
Voltage_Over_Range_Indication
1 = A Voltage over range status condition exists
0…1
Bit 5
Ampere_Over_Range_Indication
1 = An Amperage over range status condition exists
0…1
Bit 6
Wiring_Diagnostics_Active
1 = The wiring diagnostics is currently calculating wiring condition
0…1
Bit 7…15
Reserved
Reserved for future use
0
4
Int16
Over_Range_Information
Indicates which input is over range
0…65,535
Bit 0
V1G_Over_Range
1 = V1G input is over input range
0…1
Bit 1
V2G_Over_Range
1 = V2G input is over input range
0…1
Bit 2
V3G_Over_Range
1 = V3G input is over input range
0…1
Bit 3
VNG_Over_Range
1 = VNG input is over input range
0…1
Bit 4
I1_Over_Range
1 = I1 input is over input range
0…1
Bit 5
I2_Over_Range
1 = I2 input is over input range
0…1
Bit 6
I3_Over_Range
1 = I3 input is over input range
0…1
Bit 7
I4_Over_Range
1 = I4 input is over input range
0…1
Bit 8…15
Reserved
Reserved for future use
0
5
Int16
PowerQuality_Status
Power Quality Conditions Status
0…65,535
Bit 0
Sag_Indication_Detected
1 = A sag event was detected in the last metering cycle
0…1
Bit 1
Swell_Indication_Detected
1 = A Swell event was detected in the last metering cycle
0…1
Bit 2…15
Reserved
Reserved for future use
0
Table 116 - Status.Alarms Data Table
Element
Number
Type
Tag Name
Description
Range