beautypg.com

ElmoMC SimplIQ Digital Servo Drives-Bell Command Reference User Manual

Page 93

background image

IP and IB[N] can be used to detect a logically active switch of all defined

functions, excluding function 2 (“No function is attached”).

Attributes:

Type: Parameter,

Bit-field

Assignment: Yes
Source:

Program, RS-232, CANopen

Restrictions: None
Default value: IL[1]=0

IL[2…10]=7 (RS), Non-volatile

Range:

According to previous description

Index range: [1…10]
Unit modes: All
Activation: Immediate

Reference chapter in the SimplIQ for Steppers Application Note:
Chapter 12, “The Position Reference Generator”

See also:

UM

,

RM

,

JV

,

PX

,

BG

,

IP

,

IB[N]

,

HM[N]

,

HY[N]

SimplIQ for Steppers Command Reference Manual

Alphabetical Listing

MAN-STECR (Ver. 1.1)