beautypg.com

ElmoMC SimplIQ Digital Servo Drives-Bell Command Reference User Manual

Page 195

background image

Notes:

Changing YA[4] resets the position sensor thus resetting the homing position.
Changing YA[5] does not change PY. It only defines in which direction future

encoder pulses will be counted.

SimplIQ difference: Encoder output is only available for quadrature Main

encoder.

SimplIQ difference: OC[N] runs correctly regardless of the YA[4] state.

Attributes:

Type: Parameter,

Integer

Source:

Program, RS-232, CANopen

Restrictions: MO=0
Default values:

YA[1]…YA[3]=0 (RS), Non-volatile

YA[4]=2, YA[5]=0 (RS), Non-volatile

Range:

As in previous table

Index range: [1…5]
Unit modes: All
Activation: Immediate
SimplIQ: Modified

See also:

OC[N]

SimplIQ for Steppers Command Reference Manual

Alphabetical Listing

MAN-STECR (Ver. 1.1)