Notes:

The motor stuck protection is always applied to the main sensor. In dual loop

applications, this protection does not pertain to failures in the auxiliary sensor.

The time constant of 3 seconds is taken because almost every motion system

applies high torques for short acceleration periods while the speed is slow.

The minimum current limit is MC/128. If CL[1] < MC/128, the CL[1] value will

be accepted, but the actual current value will be limited to MC/128.

See also:

LC

,

MC

,

PL[N]

,

TC

,

MF

Application notes:

CL[1]:

Current limiting

CL[2], CL[3]:

Motor does not move protection

SimplIQ for Steppers Command Reference Manual

Alphabetical Listing

MAN-STECR (Ver. 1.1)

36