beautypg.com

ElmoMC SimplIQ Digital Servo Drives-Bell Command Reference User Manual

Page 64

background image

Error
Code


Error String / Description


Example / Remedy

164

EC command (not an error).

For internal use.

165

An attempt to access serial flash while busy.
Failure on reading serial flash memory,
possibly due to a hardware problem.

Contact Technical Support.

166

Out of modulo range.

XM[1]=-1000, XM[2]=1000 and
PA=2000 is an error because the
modulo range is [-1000…999].
Therefore, the position of
PA=2000 can never be reached.

167

Infinite loop in for loop - zero step

k=1:0:10; causes this error.

168

Speed too large to start motor.
MO=1 or motor started with Enable switch
while motor was rotating too quickly.

Starting a running motor may fail
if the back EMF is too high and
induces an immediate excessive
motor current.

Table 3-10: Processing Error Codes

Attributes:

Type:

Status report, Integer

Source: RS-232,

CANopen

Restrictions: None
Unit modes: All
SimplIQ: Modified

See also:

MF

,

SR

SimplIQ for Steppers Command Reference Manual

Alphabetical Listing

MAN-STECR (Ver. 1.1)