beautypg.com

ElmoMC SimplIQ Digital Servo Drives-Bell Command Reference User Manual

Page 112

background image

Notes:

• In SimplIQ for Steppers the user can set amplitude tolerances for analog encoder.

• Some internal problems are reported in SimplIQ for Steppers that are absent from

SimplIQ.

Example:
The MF report of 0x3000 indicates that the motor has been shut down due to under-
voltage. The under-voltage condition did not necessarily exist at the time the MF was
reported. It may possibly be the result of high power consumption and a high output
impedance of the power supply. In such a case, when the motor was shut down the
power consumption stopped and the power supply returned to its normal voltage.

See also:

SR

,

MO

,

TS

,

LL[N]

,

HL[N]

,

CD

,

PE

,

VE

SimplIQ for Steppers Command Reference Manual

Alphabetical Listing

MAN-STECR (Ver. 1.1)

104