Notes:

• The tuning wizard in the Composer program has a utility to find and set PN[10]

and PN[11] correctly.

• The analog index will appear to work correctly in most cases even if PN[10] and

PN[11] had never been tuned. There is however a danger: if either the PN[10]
value or PN[11] value deviate about 180° from their correct setting, the index may
be identified with the error of one full encoder line (360°), and consecutive
homing processes may yield inconsistent results.