beautypg.com

ElmoMC SimplIQ Digital Servo Drives-Bell Command Reference User Manual

Page 60

background image

Error
Code


Error String / Description


Example / Remedy

119

Bad Analog sensor Filter

When the filter KV, set for analog
feedback, is beyond its legal
range.

120

Bad number of blocks for Analog sensor
filter

When the analog sensor filter
contains a wrong number of
blocks.

121

Analog sensor is not ready

When the initiation procedure of
the Analog sensor was not
completed, and the motor is being
enabled.

123

Motion control processor does not respond.

Possibly, firmware has not been well loaded.

127

Modulo range must be positive.
XM[2] is less or equal to XM[1] or
YM[2] is less or equal to YM[1].

128

Bad variable index in database - internal
compiler error.
Index of the variable in the database is not
correct.

An internal compiler error occurs
due to a corrupted database. In
such a case, email Technical
Support for assistance. Attach the
Composer date and version (found
in the Help menu) and the program
you attempted to compile.

129

Variable is not an array.
Cannot access a scalar variable defined
according to its index in square brackets as
an array in the user program.

Assume that a scalar variable has
been defined in the user program
as a:
long a;

The expression a[0]=1; is wrong
because a is defined as scalar and
not an array.

130

Variable name does not exist.
For

SimplIQ for Steppers

internal use.

131

Cannot record local variables.
For

SimplIQ

drive internal use.

132

Variable is not an array.
For

SimplIQ

drive internal use.

SimplIQ for Steppers Command Reference Manual

Alphabetical Listing

MAN-STECR (Ver. 1.1)

52