SYSTEM SET MODULE

Syntax

system set module id=

chassis

/

slot

name=

name

temperature-threshold=

value

Parameters

id

Specifies a module in a chassis. The command can

configure only one module at a time. The ID consists of the
following parts:

chassis

Identifies a chassis ID number. The range is 0 to
31. For background information, refer to
“Chassis ID Numbers” on page 25.

slot

Specifies a slot number or letter. For
background information, refer to “Slot Numbers
and Letters” on page 26. The va
lues and ranges
are:

m

Identifies the AT-MCF2000M
Management Module or the
AT-MCF2000S Stacking Module.

1 or 2

Specifies a slot number of a media
converter module in the
AT-MCF2000 Chassis. The left slot is
1 and the right slot is 2.

1 to 4

Specifies a slot number of a media
converter module in the
AT-MCF2300 Chassis. The slots are
number 1 (left) and 2 (right) in the top
row, and 3 (left) and 4 (right) in the
bottom row.

a or b

Specifies a slot letter of a power
supply or a fan module.

To view the ID and slot numbers of a chassis, refer to
“SYSTEM SHOW CLUSTER” on page 101 or “SYSTEM
SHOW CHASSIS” on page 99. For more information, refer
to “Slot Numbers and Letters” on page 26

name

Assigns a name of up to 20 alphanumeric characters to the
module. Spaces are permitted, but a name with spaces
must be enclosed in double quotes (“ “). To remove the
current value without specifying a new value, enter “none”.