The first subsection in a Blade Configuration is illustrated in Figure 33. It
sets the operating modes of the media converter channels on the module
with a modified version of the SYSTEM SET INTERFACE command. The
ID parameter of the command is replaced with a PORTID parameter,
which specifies the channel number. For example, PORTID=1 designates
channel 1, which on the AT-MCF2012LC and AT-MCF2012LC/1 Media
Converter Modules represents twisted pair port 1 and fiber optic port 1,
PORTID=2 designates channel 2 of twisted pair port 2 and fiber optic port
2, and so on.

Figure 33. Blade Configuration - Operating Mode Section

Review the following guidelines before modifying the commands in this
section:

ˆ

Each channel must have its own command line.

ˆ

If you delete a command, the corresponding channel’s operating mode
will be Link Test, the default value.

ˆ

As previously mentioned, the PORTID parameter must specify just the
channel number. Do not include a chassis ID number or slot number.
The latter are defined in the header lines of the Blade Configuration
section.

The next subsection in a Blade Configuration, shown in Figure 34,
configures the operating parameters of the ports on the media converter
module, both twisted pair and fiber optic. The port operating parameters
are set with a modified version of the SYSTEM SET PORT command,
where the values in the ID parameter are truncated to the channel number
and port letter. For a description of this command, refer to “SYSTEM SET
PORT” on page 92.

### Blade Configuration

system set interface portId=1 OpMode=link-test
system set interface portId=2 OpMode=link-test
system set interface portId=3 OpMode=link-test
system set interface portId=4 OpMode=link-test
system set interface portId=5 OpMode=link-test