Diagnostics show module – Allied Telesis AT-S97 User Manual
Page 232

Chapter 14: Diagnostics Commands
232
DIAGNOSTICS SHOW MODULE
Syntax
diagnostics show module id=
chassis
/
slot
Parameters
id
Specifies a module. You can view only one module at a
time. The ID consists of the following parts:
chassis
Identifies an ID number of a chassis. The range
is 0 to 31. The ID number of a chassis with a
management module is either 0 or 31. The
range of the ID number for a chassis with a
stacking module is 1 to 30. For background
information, refer to “Chassis ID Numbers” on
page 25.
slot
Specifies a letter or an ID number of a slot with
a module you want to reset. Slot numbers are
explained in “Slot Numbers and Letters” on
page 26. The possible values are:
1 or 2
Specifies a slot number of a media
converter module in the
AT-MCF2000 Chassis. The left slot
is 1 and the right slot is 2.
1 to 4
Specifies a slot number of a media
converter module in the
AT-MCF2300 Chassis. The slots are
number 1 (left) and 2 (right) in the top
row, and 3 (left) and 4 (right) in the
bottom row.
m
Identifies the management slot with
the AT-MCF2000M Management
Module.
To view the ID and slot numbers of a chassis, refer to
“SYSTEM SHOW CHASSIS” on page 99 or “SYSTEM
SHOW CLUSTER” on page 101.
Privilege Levels
Administrator, read-write, and read-only.