Allied Telesis AT-S97 User Manual
Page 234

Chapter 14: Diagnostics Commands
234
Examples
This command displays information about the management module in a
chassis with the ID 0:
diagnostics show module id=0/m
This command displays information about the media converter module in
slot 2 of a chassis with the ID 1:
diagnostics show module id=1/2
SN
Displays the serial number of a module.
HW Rev
Displays the hardware revision levels of the component.
Software Version
The version number of the AT-S85 or AT-S97 Management
Software.
Voltages
Displays the module’s input voltages.
Temperature
Displays the current temperature of the module.
Temperature Threshold
Displays the temperature threshold of a module. The
management module logs an event in the event log if the
threshold is exceeded, to warn of possible excessive
temperature in the wiring closet or chassis. Refer to “SYSTEM
SET MODULE” on page 89 for instructions on setting a
module’s temperature threshold.
Table 28. DIAGNOSTICS SHOW CHASSIS EEPROM Command
Parameter
Description