beautypg.com

System reset module – Allied Telesis AT-S97 User Manual

Page 78

background image

Chapter 5: Port and Module Commands

78

SYSTEM RESET MODULE

Syntax

system reset module id=

chassis

/

slot

Parameters

id

Identifies a media converter module or management
module to be reset. An ID number has the following parts:

chassis

Identifies an ID number of a chassis. The range
is 0 to 31. For background information, refer to
“Chassis ID Numbers” on page 25.

slot

Identifies the module to be reset by its slot

number or letter. For background information,
refer to “Slot Numbers and Letters” on page 26.
Possible values are:

1 or 2

Specifies a slot number of a media
converter module in the
AT-MCF2000 Chassis. The left slot
is 1 and the right slot is 2.

1 to 4

Specifies a slot number of a media
converter module in the
AT-MCF2300 Chassis. The slots are
number 1 (left) and 2 (right) in the top
row, and 3 (left) and 4 (right) in the
bottom row.

m

Identifies the AT-MCF2000M
Management Module.

To view the ID and slot numbers of a chassis, refer to

“SYSTEM SHOW CHASSIS” on page 99 or “SYSTEM
SHOW CLUSTER” on page 101.

Privilege Levels

Administrator and read-write.

Description

This command is used to perform a soft reset on a media converter
module or management module in a chassis. The module initializes its
management software. You might reset a module if it is experiencing a
problem.