After you’ve performed this command, you must do the following before
you can save new parameter changes:
1. Create a new master configuration file on the management module or
download a previously saved file to the module from a TFTP server. To
create a new file, refer to “Creating a Master Configuration File” on
page 32 or “CONFIG SAVE FILESYSTEM” on page 162. To download
a configuration file from a TFTP server, refer to “FILE DOWNLOAD” on
page 179.
2. Designate the file as the management module’s active master
configuration file. For instructions, refer to “CONFIG SET” on
page 164.
3. If you downloaded a new master configuration file onto the
management module from a TFTP server and want to configure the
modules using the parameter settings in the file, issue the CONFIG
RUN command. For instructions, refer to “CONFIG RUN” on page 160.
Review the following before performing this command:
The current date and time are retained.
The command does not affect the power supply or fan modules.
This command ends your management session. To continue
managing the unit, start a new session after the management module
initializes its AT-S97 Management Software. The initialization process
takes approximately one minute.
Example
This command restores the default settings to all of the management and
media converter modules in the chassis or stack by deleting all of the
master and auxiliary configuration files on the modules:
system reset cluster