CONFIG OVERWRITE

Syntax

config overwrite enable|disable id=

chassis

/

slot

Parameters

enable

Activates configuration overwrite on a media converter

module. At this setting, a module, when it is powered on or
reset, seeks its configuration settings from a management
card and a master configuration file. This is the default
value.

disable Deactivates

configuration

overwrite on a media converter

module. At this setting, a module uses the configuration
settings in its auxiliary configuration file in flash memory to
set its parameter settings whenever it is powered on or
reset.

id

Identifies a media converter module. You can configure
only one module at a time. An ID number has the following
parts:

chassis

Identifies an ID number of a chassis. The range
is 0 to 31. For background information, refer to
“Chassis ID Numbers” on page 25.

slot

Identifies a slot number of a module to be

configured. For background information, refer to
“Slot Numbers and Letters” on page 26. The
possible values are:

1 or 2

Specifies a media converter slot in
the AT-MCF2000 Chassis. The left
slot is 1 and the right slot is 2.

1 to 4

Specifies a media converter slot in
the AT-MCF2300 Chassis. The slots
are number 1 (left) and 2 (right) in
the top row, and 3 (left) and 4 (right)
in the bottom row.

Privilege Levels

Administrator and read-write.

This manual is related to the following products: