AT-S85 and AT-S97 Management Software User’s Guide

141

Stacking Port Link

A Stack port on the management module or the
AT-MCF2000S Stacking Module established or lost
its link to another Stack port.

Report

Major Level Messages

Chassis Managership
Acquire

A media converter module assumed control of the
backplane in the chassis to determine system
information, as it was initializing its management
software.

Report

Chassis Managership
Release

A media converter module released control of the
backplane.

Report

Chassis Reset

The chassis was reset with the SYSTEM RESET
CHASSIS command.

Report

Cold Boot

A media converter module loaded its boot loader and
management software after receiving power. It
generates this message when the chassis is
powered on or if it is installed while a unit is powered
on.

Report

Fan # Failure

A cooling fan in a power supply or fan module
stopped.

Report

A cooling fan resumed operating after having
stopped.

Clear

High Temperature
Threshold

A module’s operating temperature exceeded the
temperature threshold set with the SYSTEM SET
MODULE command.

Report

A module’s operating temperature returned below its
temperature threshold.

Clear

Module Reset

A media converter module started the process of
initializing its boot loader and AT-S85 Management
Software after it was reset with the SYSTEM RESET
MODULE command. The completion of the
initialization process is signaled with the Warm Boot
message.

Report

Warm Boot

A media converter module completed the
initialization of its management software after being
reset with the SYSTEM RESET MODULE
command.

Report

Table 18. Event Messages (Continued)