75
Note
When the AT-MCF2000M Management Module is reset, it will be
unresponsive to commands for approximately one minute while it
initializes its AT-S97 Management Software.
Review the following before performing this command:
The command does not affect the power supply and fan modules.
If the chassis you’re resetting has the management module, you’ll
have to reestablish your management session after the module has
initialized its AT-S97 Management Software, if you want to continue to
manage the unit. The initialization process takes approximately one
minute to complete.
Note
Any parameter settings that you have not saved in the active master
configuration file on the management module are discarded during
the reset. To save your changes, use the CONFIG SAVE command.
For instructions, refer to “CONFIG SAVE” on page 161.
To reset individual modules, refer to “SYSTEM RESET MODULE” on
page 78.
Examples
This command resets the chassis with the ID number 0:
system reset chassis id=0
This command resets the chassis with the ID number 2:
system reset chassis id=2