Configuring specific snmp traps – Brocade Mobility 7131N-FGR Access Point Product Reference Guide (Supporting software release 4.0.0.0-35GRN and later) User Manual

Page 96

background image

84

Brocade Mobility 7131N-FGR Product Reference Guide

53-1001947-01

Configuring SNMP settings

4

6. Click Logout to securely exit the Brocade Mobility 7131N-FGR Access Point Access Point

applet. A prompt displays confirming the logout before the applet is closed.

Configuring specific SNMP traps

Use the SNMP Traps screen to enable specific traps on the Brocade Mobility 7131N-FGR Access
Point. Brocade recommends defining traps to capture unauthorized devices operating within the
Brocade Mobility 7131N-FGR Access Point coverage area. Trap configuration depends on the
network machine that receives the generated traps. SNMP v1/v2c and v3 trap configurations
function independently. In a mixed SNMP environment, traps can be sent using configurations for
both SNMP v1/v2c and v3. To configure specific SNMP traps on the Brocade Mobility 7131N-FGR
Access Point:

1. Select System Configuration - > SNMP Access - > SNMP Traps from the menu tree.

CAUTION
Ensure IPSec has been properly configured to protect communications with the external SNMP
server. Changes will not be applied otherwise.

2. Configure the MU Traps field to generate traps for MU associations, MU association denials

and MU authentication denials. When a trap is enabled, a trap is sent every 10 seconds until
the condition no longer exists.