4. RC Gateway Function setting
65
4.3.2 Slave (axis to be controlled) Setting
(1) In the case of PCON, ACON, SCON-CA
The setting of the slave axis controllers is to be conducted by connecting a teaching tool such as the
PC software to one controller after another. In this section, explains how to conduct the settings with
using the PC software (RC PC Software: RCM-101-ƑƑƑ).
[Preparation 1] Connection to PC
PC Software Accessory Cable
( RS232C
⇔
RS485 conversion unit
or
USB
⇔
RS485 with converter adapter)
[Procedure 1] Axis number setting
Set the axis number of the slave controller in a hexadecimal number to the rotary switch
on the front panel.
Setting axis number 0 Setting axis number 1 Setting axis number 10
Axis No. Setting
Rotary Switch