5. Program Creating
110
X-SEL
ż: Valid
z
RGVL (Read RC axis speed data)
RC position
data mode
RC
×: Invalid
(Note 1)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration Operand 1
Operand 2
Output operation
type (output, flag)
Free
Free
RGVL
RC axis
number
Position
number
CP
Note 1 If the command is executed, an RC position data use method error (439) will occur.
[Function]
Read the speed [mm/s] for the position data specified by operand 2, into variable 199.
[Example]
RGVL
2
1
Read the speed for RC position No.1 of axis 2 into variable
199.
Position data of axis 2
No.
Pos
Vel
Acc
Push
Inp
0
5.00
300
0.3
0
0.10
1
380.00
200
0.3
0
0.10
Variable 199
200
X-SEL
ż: Valid
z
RGAD (Read RC axis acceleration/deceleration
data)
RC position
data mode
RC
×: Invalid
(Note 1)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration Operand 1
Operand 2
Output operation
type (output, flag)
Free
Free
RGAD
RC axis
number
Position
number
CP
Note 1 If the command is executed, an RC position data use method error (439) will occur.
[Function]
Read the acceleration/deceleration [G] for the position data specified by operand 2, into
variable 199.
[Example]
RGAD
2
1
Read the acceleration/deceleration for RC position No.1 of
axis 2 into variable 199.
Position data of axis 2
No.
Pos
Vel
Acc
Push
Inp
0
5.00
300
0.3
0
0.10
1
380.00
300
0.2
0
0.10
Variable 199
0.2