6.

Appendix

139

New system started?

(Here, a new system includes a system that has been assembled anew based on an existing design.)

[1] Invalid axis number setting of the added controller o [Check] *3

[2] Invalid baud rate setting of the added controller o [Check] *4

[3] Invalid transmitter activation time setting of the added controller

o

[Check] *4

[4] Inappropriate installation position of the terminal resistor

o

[5] Wrong setting in the slave input and output size

o

[Check Section 4.3.1]

[6] Operation mode is set to MANU Mode on the controller.

o

[Switch over to AUTO Mode]

[7] Wrong setting in the node addresses

o

[Check Section 4.3.1 and 4.3.2]

[8]Wrong setting in the fieldbus operation mode

o

[Check Section 4.3.1]

Problem occurred after relocation?

Problem occurred after relocation o [1] Open communication cable o [Repair the open cable]

[2] Loose communication cable connector

o

[Check the connection]

Problem occurred after addition of controller?

Problem occurred after a

controller was added o

Communication disabled with all controllers?

[Check the connection using RC PC Software for SIO Type] *1

Communication is disabled

with all controllers

o

[1] Inappropriate wiring of the communication cable

between the host and junction o [Check the wiring] *2

[2] Abnormal power supply of the system

o

[Check the power-supply voltage]

p

[3] Duplicate controller axis number o [Check] *3

[4] Inconsistent controller baud rate setting o [Check] *4

Continue to the next page

○→

Apply a terminal resistor to the junction

(for SIO type) or junction tap (for Fieldbus

type) that is furthest from the host

Check if a common 0V line is used

o

[Use a common 0V line]

Continued from the previous page

1), 2) and 3) are SIO type

5), 7) and 8) are Fieldbus type