4. RC Gateway Function setting
64
[Procedure 4] Writing Process of Changed Parameters to Memory
Click the parameter send button to send the changed parameters to X-SEL and then write
into the flash ROM.
A confirmation window appears to ask whether to software reset X-SEL. Select the reset.
Caution㧦 After the parameter is written to the Flash ROM, Error Code 6A1 (UBM Data
Construction Change Error) will be generated if the software reset is performed. In
case this error is issued, see below for how to cancel the error.
In such a case, click on Controller (C) o Memory Initializing (I) o User Data
Retaining Memory (U) in XSEL PC Software to perform an initializing of the memory.
After writing into the flash ROM, perform a software reset or reboot the power.
By initializing the memory, the capacity in RC position data is ensured and the error
will be solved.
1) Parameter send button
2) Yes
3) OK
4) Yes