4. RC Gateway Function setting

64

[Procedure 4] Writing Process of Changed Parameters to Memory

Click the parameter send button to send the changed parameters to X-SEL and then write

into the flash ROM.

A confirmation window appears to ask whether to software reset X-SEL. Select the reset.

Caution㧦 After the parameter is written to the Flash ROM, Error Code 6A1 (UBM Data

Construction Change Error) will be generated if the software reset is performed. In

case this error is issued, see below for how to cancel the error.

In such a case, click on Controller (C) o Memory Initializing (I) o User Data

Retaining Memory (U) in XSEL PC Software to perform an initializing of the memory.

After writing into the flash ROM, perform a software reset or reboot the power.

By initializing the memory, the capacity in RC position data is ensured and the error

will be solved.

1) Parameter send button

2) Yes

3) OK

4) Yes

This manual is related to the following products: