5. Program Creating

111

X-SEL

ż: Valid

z

RGIP (Read RC axis positioning band data)

RC position

data mode

RC

×: Invalid

(Note 1)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,

declaration Operand 1

Operand 2

Output operation

type (output, flag)

Free

Free

RGIP

RC axis

number

Position

number

CP

Note 1 If the command is executed, an RC position data use method error (439) will occur.

[Function]

Read the positioning band [mm] for the position data specified by operand 2, into variable 199.

[Example]

RGIP

2

1

Read the positioning band for RC position No.1 of axis 2

into variable 199.

Position data of axis 2

No.

Pos

Vel

Acc

Push

Inp

0

5.00

300

0.3

0

0.10

1

380.00

300

0.2

0

0.10

Variable 199

0.10

X-SEL

ż: Valid

z

RGTQ (Read RC axis current-limiting value data

during push-motion operation)

RC position

data mode

RC

×: Invalid

(Note 1)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,

declaration Operand 1

Operand 2

Output operation

type (output, flag)

Free

Free

RGTQ

RC axis

number

Position

number

CP

Note 1 If the command is executed, an RC position data use method error (439) will occur.

[Function]

Read the current-limiting value during push-motion operation [%] for the position data

specified by operand 2, into variable 199.

[Example]

RGTQ

2

1

Read the current-limiting value for RC position No.1 of axis

2 into variable 199.

Position data of axis 2

No.

Pos

Vel

Acc

Push

Inp

0

5.00

300

0.3

0

0.10

1

380.00

300

0.2

30

0.10

Variable 199

30