5. Program Creating
111
X-SEL
ż: Valid
z
RGIP (Read RC axis positioning band data)
RC position
data mode
RC
×: Invalid
(Note 1)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration Operand 1
Operand 2
Output operation
type (output, flag)
Free
Free
RGIP
RC axis
number
Position
number
CP
Note 1 If the command is executed, an RC position data use method error (439) will occur.
[Function]
Read the positioning band [mm] for the position data specified by operand 2, into variable 199.
[Example]
RGIP
2
1
Read the positioning band for RC position No.1 of axis 2
into variable 199.
Position data of axis 2
No.
Pos
Vel
Acc
Push
Inp
0
5.00
300
0.3
0
0.10
1
380.00
300
0.2
0
0.10
Variable 199
0.10
X-SEL
ż: Valid
z
RGTQ (Read RC axis current-limiting value data
during push-motion operation)
RC position
data mode
RC
×: Invalid
(Note 1)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration Operand 1
Operand 2
Output operation
type (output, flag)
Free
Free
RGTQ
RC axis
number
Position
number
CP
Note 1 If the command is executed, an RC position data use method error (439) will occur.
[Function]
Read the current-limiting value during push-motion operation [%] for the position data
specified by operand 2, into variable 199.
[Example]
RGTQ
2
1
Read the current-limiting value for RC position No.1 of axis
2 into variable 199.
Position data of axis 2
No.
Pos
Vel
Acc
Push
Inp
0
5.00
300
0.3
0
0.10
1
380.00
300
0.2
30
0.10
Variable 199
30