IAI America XSEL-S User Manual
Page 127
![background image](/manuals/350292/127/background.png)
5. Program Creating
121
(3) Information read commands
X-SEL
ż: Valid
z
RCST (Read RC axis status)
RC position
data mode
RC
ż: Valid
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration Operand 1
Operand 2
Output operation
type (output, flag)
Free
Free
RCST
Variable
number
RC axis
number
CP
[Function]
Read the RC axis status into variable No.n specified by operand 1.
Read the completed position number into variable No.n+1. (Refer to Notice 2.)
Notice 1: The specific status varies depending on whether the X-SEL position data mode or RC
position data mode is used.
Variable number
Acquired item
n
RC axis status
n + 1
Completed position number
Bit structure of RC axis status
Method to use position data in X-SEL
Method to use position data in RC
Bit
Name
Explanation
Name
Explanation
27-31
-
Reserved.
-
Reserved.
26
ALMX
RC axis alarm
(Alarm detected by the X-SEL)
* ALMX is a RC-axis alarm that ALM + X-SEL
have detected.
ALMX
RC axis alarm
(Alarm detected by the X-SEL)
* ALMX is a RC-axis alarm that ALM +
X-SEL have detected.
25
USE RC axis in use
USE RC axis in use
24
LNK RC axis link status
LNK RC axis link status
16-23
-
Reserved.
-
Reserved.
15
RMDS Operation Mode
RMDS Operation Mode
14
ALML Light Error Alarm
ALML Light Error Alarm
13
ZON2 Zone 2
ZON2 Zone 2
12
ZON1 Zone 1
ZON1 Zone 1
11
-
Reserved.
PZON Position zone
10
-
Reserved.
MODS Teaching mode status
9
SFTY Safety speed enabled status
SFTY Safety speed enabled status
8
BALM Low battery voltage
BALM Low battery voltage
7
EMG Emergency stop status
EMG Emergency stop status
6
PSFL Load missed during push-motion operation
PSFL Load missed during push-motion operation
5
CRDY Controller ready
CRDY Controller ready
4
SON Servo ON status
SON Servo ON status
3
MOVE Moving
MOVE Moving
2
HEND Home return complete
HEND Home return complete
1
PEND Positioning complete
PEND Positioning complete
0
ALM
An alarm occurred that makes it impossible
to continue operation.
(Alarm detected by the RC axis)
ALM
An alarm occurred that makes it impossible
to continue operation.
(Alarm detected by the RC axis)
Notice 2: Completed position numbers are set only in the RC position data mode.
In the X-SEL position data mode, “0” is always set.
[Example]
RCST
200
10
Get the status of RC axis 10 into variable 200.