Level

No.

Error name

Description/action

438 RC position number error (SEL) The RC position number is not specified correctly.

o

Check the RC position number.

439 RC position data use method

error (SEL)

An operation cannot be made with the current position

data use method. An unavailable SEL command is

executed.

ĺ

Check the program. Check Bits 0 to 11 in I/O

Parameter No. 216.

43A RC gateway status error

The applicable operation cannot be performed in the

current RC gateway status.

x

Gateway Status : Condition to perform normal

operation

x

PC Software Connection Status

: Condition to connect RC PC

Software via X-SEL

An operation commands from X-SEL such as RC

Gateway SEL Command are prohibited. This error will

be generated in such cases.

The switchover of conditions is to be conducted with

“GW” and “RC” buttons in the menu bar of X-SEL PC

Software.

o

When operating RC axes from X-SEL, press “GW”

button in X-SEL PC Software.

43B RC axis pattern not yet set error No PC axis pattern has been set.

o

Issue the RAXS command.

43C Servo OFF for RC axis in use

error

The servo for the RC axis in use (= target axis of the

processing in progress) turned OFF.

o

Check if there is duplication in the use of RC axis

among multiple programs.

43D RC axis multiple-use error

(SEL)

An attempt was made to get the right of use over an

RC axis that is already is in use.

o

Check if there is duplication in the use of RC axis

among multiple programs.

43E Error RC axis used error

An attempt was made to use the RC axis currently

generating an error.

o

Reset the error generated by the applicable RC

controller.

(For information on how to reset the applicable error,

refer to the operation manual for each RC controller.)

43F RC axis right-of-use acquisition

error

No space is available in the RC-axis use management

area.

o

Contact IAI.

440 Servo-off RC axis used error An attempt was made to use an RC axis whose servo

is currently turned OFF.

o

Turn ON the servo.

441 RC axis not yet completed

home return error

The RC axis has not yet completed home return.

o

Perform home return operation.

(Execute the RHOM command.)

Operation

cancellation

442 Inappropriate RC axis position

after positioning error

The RC axis position upon completion of RC axis

positioning is inappropriate with respect to the position

specified in the X-SEL command.

(This error occurs only in the RC position data

specification mode.)