Delete
This field displays the reason for not being able to delete an X6004 from
the ZyStack. The field displays as the following followed by hyphen and a
ZyStack X6004 serial number. For example, “timeout-b471c385” where
b471c385 is a serial number.
• timeout displays if the master X6004 was unable to establish a
connection with the X6004 that you wanted to remove from the
ZyStack.
• wrong master displays if the X6004 is already a member of another
ZyStack.
• wrong serial displays if the serial number did not match when
removing this X6004 from the ZyStack.
• N/A displays when the delete function was not performed or X6004(s)
were successfully deleted from the ZyStack.
ZyStack Add
Failure Log
This table is a list of log entries regarding successful and unsuccessful
attempts to add X6004s to the ZyStack.
Machine ID
This field displays the system name of the X6004. The system name is
automatically assigned to the X6004 based on when it was added to the
ZyStack. IPPBX_001 is always the master followed by slaves
IPPBX_002, IPPBX_003 and so on.
Serial
This field displays the serial number that was entered when trying to add
this X6004 to the ZyStack.
Fail Reason
This field displays the reason for not being able to add an X6004 to the
ZyStack. The field displays:
• timeout - if the master X6004 was unable to establish a connection
with the X6004 that wanted to join the ZyStack.
• wrong master - if the X6004 is already a member of another
ZyStack.
• wrong serial - if an incorrect serial number was entered when adding
this X6004 to the ZyStack.
Clear Log
Click the Clear button to erase a ZyStack failure log.
Table 135 ZyStack Status (continued)
LABEL
DESCRIPTION