Quick Keys
Parameter
Default
Range
ZZ
I+ Exit/Entry 1 (Interior+ Exit/Entry 1)
Used for Exit/Entry doors, as follows:
If the system is armed in the AWAY (ARM) mode, the zone(s)
provide a delay (specified by Exit/Entry 1) allowing entry into and
exit from an armed premises.
If the system is armed in the STAY mode, the zone is bypassed.
Important:
For greater security when arming in the STAY mode, it is possible to
eliminate the Entry Delay period associated with any zone(s), classified
as Exit/Entry Delay 1 by pressing the
key twice, one after another.
In effect, this makes it an INSTANT zone during the STAY mode of
operation
ZZ
I + Exit/Entry 2
(Interior + Exit/Entry 2)
Same as the I+Exit/Entry 1 parameter, described above, but the
Exit/Entry 2 time period is applicable.
ZZ
I + Exit(OP)/Entry 1
Interior + Exit(OP)/Entry 1)
Used for an exit/entry door that, for convenience, may be kept open
when the system is being armed, as follows:
In AWAY (FULL ARM) mode behaves as an Exit (Op)/Entry 1 zone
(see
ZZ
above
).
In STAY (ARMED) mode, the zone will be bypassed.
ZZ
I + Exit(OP)/Entry 2
Interior + Exit(OP)/Entry 2)
Used for an exit/entry door that, for convenience, may be kept open
when the system is being armed, as follows:
In AWAY (FULL ARM) mode behaves as an Exit (Op)/Entry 2 zone
(see
ZZ
above
).
In STAY (ARMED) mode, the zone will be bypassed.
ZZ
I+ Entry Follow
(Interior + Entry Follower)
Generally used for motion detectors and/or interior doors (for example,