RISCO Group LightSYS 2 User Manual
Page 104

Installer Programming
Page 104
Quick Keys
Parameter
Default
Range
ZZ
Key Box
This zone is mainly used in Scandinavia. Triggering this zone will be
recorded in the event log. It can also be reported to the monitoring
station. No alarm is triggered.
When using this zone you should connect the alarm wiring of this zone
(usually the auxiliary contact of a door) to an external key box and the
tamper wiring to the housing switch.
ZZ
KeySwitch Arm
This zone is used by financial institutions such as cash distribution
centers and banks to control the arming of the vault door or treasury
department entrance.
Use this zone for instant arming of the partition in which the zone is
allocated. This zone cannot perform disarming operation.
ZZ
KeySwitch Delayed Arm
Same as the KeySwitch Arm
(
ZZ
)
type but the arming will
be delayed following exit delayed time.
Sound
This menu enables you to program the sound produced when a systems
zone triggers and alarm. Report to the central station are not affected by
the option of this menu.
The following sound can be selected:
Silent: Produces no sound
Bell Only: Activates the bell sounders for the duration of the Bell
Timeout period, or until a User Code is entered
Buzzer Only: Activates each keypadʹs internal piezo buzzer.
Bell + Buzzer: Activates the bell sounders and the keypadsʹ buzzers
simultaneously
Door Chime: The Door Chime parameter is used as an audible
sounder to indicate the violation of a zone(s), as follows:
o
If the system is DISARMED, the systemʹs keypad buzzers make
three momentary sounds whenever the zone is violated.
o
If the system is ARMED, only the bell sounders produce the
alarm.
A different sound can be defined according to the system status as
follows