RISCO Group LightSYS 2 User Manual
Page 91

Installer Programming
Page 91
System: Sounds: Tamper
Quick Keys
Parameter
Default
Range
During Disarm
Buzzer
–
Sets the sound produced by tamper violation while the system is
disarmed
During Arm
Bell only
–
Set the sound produced by tamper violation while the system is armed
Speaker Volume
Sets the volume of internal sounder (speaker) connected to the
Bells+/LS‐ terminal according to different system modes. The volume
range is between 0 (Silent) and 9 (Max volume). After changing the
volume, sound will be emitted by the internal sounder to enable
evaluation of the selected volume level.
Trouble
9
0‐9
Determines the volume of the internal sounder beeps while there is
trouble in the system
Chime
9
0‐9
Determines the volume of internal sounder chime sound. The Chime
sound is used as an audible indication to a zone violation while the
system is Disarmed.
Exit/Entry
9
0‐9
Determines the volume of the beeps sounded from the internal sounder
during the Exit/Entry times
Alarm
9
0‐9
Wireless Lost Sound
Sets the behavior of the sound when a wireless loss zone is detected. The
sound can be activated as in a fault condition or as in a tamper condition.
As trouble
As tamper
Determines the internal sounder volume during alarm