Installer Event Log Messages

Page 230

Event Message 

Description 

Bell tmp rs 

Bell tamper alarm restore 

Box tamper       

Box tamper alarm from main unit 

Box tmp rs   

Box tamper alarm restore 

Bypass Box+Bell  

Box + Bell tamper is bypassed 

Byp Trbl C=xx 

System troubles were bypassed by user XX 

Bypass Zn=xx   

Zone no. XX is bypassed 

Charge Curr S=y 

Battery charging trouble in siren ID=Y 

Chng code=xx   

Changing user code XX 

Change FM=yy     

Changing Follow‐Me number YY 

CHNG PROG=xx 

Change in the Access Control definitions of daily program, 
weekly program or access group. Each change will appear in 2 
events. The first XX defines the quick key function. The second 
XX defines the program number (for example, Access Group 04)  

Charge Current RS S=y 

Battery charging trouble restore in siren ID=Y 

Clk not set    

Time is not set 

Clk set C=xx   

Time defined by user no. XX 

Cloud Comm.Trbl  

Communication problems with the cloud channel 

Cloud Connected  

  Cloud communication channel is functioning 

Cloud Disconnect  

Cloud communication channel is not functioning 

Cloud Login Err  

Login problems with the cloud channel 

CO Alarm Z=xx   

CO alert from zone XX defined as a CO detector 

CO Rst. Z=xx    

CO alert restored from zone XX defined as a CO detector 

Comm OK IPC   

Communication OK between the LightSYS2 and IP card 

Comm OK KP=y 

Bus communication restore with keypad ID=Y 

Comm OK KR=y 

Bus communication OK with Proximity Key Reader Y 

Comm OK VOICE 

Bus communication OK with Advanced Voice module 

Comm OK WME=y 

Bus communication OK with wireless module expander ID=Y 

Comm OK BZE=y 

Bus communication OK with Bus Zone Expander ID=Y 

Comm OK PS=y 

Bus communication restore with power supply expander ID=Y 

Comm OK Siren=y 

Communication OK between the LightSYS2 and Siren Y 

Comm OK UO=y 

Bus communication restore with UO expander ID=Y 

Comm OK Z=xx 

Bus communication OK with Bus zone XX 

Comm OK ZE=y 

Bus communication restore with zone expander ID=Y 

Comm. OK GSM     

Communication OK between the LightSYS2 and GSM 

Comm.OK LRT 

Communication OK between the LightSYS2 and the long range 
transmitter