RISCO Group LightSYS 2 User Manual
Page 230
Installer Event Log Messages
Page 230
Event Message
Description
Bell tmp rs
Bell tamper alarm restore
Box tamper
Box tamper alarm from main unit
Box tmp rs
Box tamper alarm restore
Bypass Box+Bell
Box + Bell tamper is bypassed
Byp Trbl C=xx
System troubles were bypassed by user XX
Bypass Zn=xx
Zone no. XX is bypassed
Charge Curr S=y
Battery charging trouble in siren ID=Y
Chng code=xx
Changing user code XX
Change FM=yy
Changing Follow‐Me number YY
CHNG PROG=xx
Change in the Access Control definitions of daily program,
weekly program or access group. Each change will appear in 2
events. The first XX defines the quick key function. The second
XX defines the program number (for example, Access Group 04)
Charge Current RS S=y
Battery charging trouble restore in siren ID=Y
Clk not set
Time is not set
Clk set C=xx
Time defined by user no. XX
Cloud Comm.Trbl
Communication problems with the cloud channel
Cloud Connected
Cloud communication channel is functioning
Cloud Disconnect
Cloud communication channel is not functioning
Cloud Login Err
Login problems with the cloud channel
CO Alarm Z=xx
CO alert from zone XX defined as a CO detector
CO Rst. Z=xx
CO alert restored from zone XX defined as a CO detector
Comm OK IPC
Communication OK between the LightSYS2 and IP card
Comm OK KP=y
Bus communication restore with keypad ID=Y
Comm OK KR=y
Bus communication OK with Proximity Key Reader Y
Comm OK VOICE
Bus communication OK with Advanced Voice module
Comm OK WME=y
Bus communication OK with wireless module expander ID=Y
Comm OK BZE=y
Bus communication OK with Bus Zone Expander ID=Y
Comm OK PS=y
Bus communication restore with power supply expander ID=Y
Comm OK Siren=y
Communication OK between the LightSYS2 and Siren Y
Comm OK UO=y
Bus communication restore with UO expander ID=Y
Comm OK Z=xx
Bus communication OK with Bus zone XX
Comm OK ZE=y
Bus communication restore with zone expander ID=Y
Comm. OK GSM
Communication OK between the LightSYS2 and GSM
Comm.OK LRT
Communication OK between the LightSYS2 and the long range
transmitter