beautypg.com

Chapter 2 mounting and wiring – RISCO Group LightSYS 2 User Manual

Page 22

background image

Mounting and Wiring

Page 22

Chapter 2 Mounting and Wiring

This chapter covers the installation and wiring of the LightSYS2 main unit. Due to its 
modularity, the specific component assembly will depend on your system configuration. The 
following assembly is presented in the recommended order.  

LightSYS2 installation steps

The following workflow illustrates the recommended method for installing the LightSYS2. A 
detailed description is provided in the following sections of the manual.  

1. Create an installation plan. 
2. Mount the LightSYS2 to the wall. 
3. Plug in the AC adaptor and main board inside the LightSYS2 enclosure. 
4. Wire the main panel (zones, outputs etc.). 
5. Connect telephone line.  
6. Plug in communication modules. 
7. Allocate and connect bus expansion modules. 
8. Set dipswitches and jumpers on the main board and on the various expanders. 
9. Connect backup battery and AC power. 
10. Perform automatic setting and complete system programming. 

Choosing the mounting location

Before you mount the LightSYS, study the premises carefully in order to choose the exact 
location of the unit for the best possible coverage and yet easily accessible to expanders and 
accessories and prospective users of the alarm system. Among the mounting location 
considerations are the following: 

Centrality of location among all the transmitters. 

Proximity to  

o

An uninterrupted AC outlet.   

o

A communication (telephone/internet) outlet. 

Distance from sources of interference, such as: 
o

Direct heat sources 

o

Electrical noise such as computers, televisions etc. 

o

Large metal objects, which may shield the antenna.  

Alarm location effectiveness for hearing part arming mode annunciation 

Dryness 

(In case you installed GSM / GPRS module before mounting the system into the 
desired position) Ensure a good signal of the GSM network (Advisable to have a 
level of at least 4 out of 5).  

Note:

For wiring distance and grounding placement considerations, refer to Appendix A Technical 
Specifications