RISCO Group LightSYS 2 User Manual
Page 111

Installer Programming
Page 111
Quick Keys
Parameter
Default
Range
ZZ
Automatic Microwave Bypass
No
Defines whether the MW channel will be bypassed or not while the
detector identifies trouble in the MW channel.
NO ‐ While detecting a problem in the MW channel it is not bypassed.
Alarm condition cannot be established until the MW channel is fixed.
YES ‐ Switches the detector to operate only in PIR mode in case of
MW trouble
ZZ
Green Line
Yes
A feature that follows environmental guidelines by avoiding surplus
emission This feature defines the activation of the microwave channel
while the system is disarmed.
NO ‐ Green Line feature is disabled. MW is constantly activated.
YES ‐ Green Line feature is activated.
ZZ
Anti‐Mask
Enable
Defines the operation of Anti Masking detection.
DISABLE ENABLE and behaves according to the settings defined in
quick keys
ZZ
ZZ
Arm/Disarm
No
Defines the operation of the anti masking detection while the detector is
armed or disarmed
.
.
NO – While armed or disarmed, anti‐mask behaves according to the
setting defined in quick keys
ZZ
above.
YES – While armed, anti‐mask is disabled. When detector is disarmed
Anti‐mask behaves according to the settings defined in quick keys
ZZ
.
ZZ
Self Test
Remote
Used to test the detection technologies. In the event of a failed test, a Self
Test Trouble is created
REMOTE (Manual) ‐ The remote self test is performed by the system
when a user manually selects the Diagnostics option from the
Maintenance menu via the LightSYS2 User Functions menu
LOCAL (automatic) ‐ Once an hour, the detector automatically checks
that the detector’s channels are functioning properly.