ZZ
Abort Alarm
This parameter defines whether a zone alarm report to the monitoring
station will be immediate or delayed:
ENABLE
: A report to the MS will be delayed according to the Abort
Time Delay parameter 5) Communication > 2 MS > 6 MS Times > 2
Abort Alarm,
page 161).
DISABLE:
A report to the MS will be sent immediately
Quick Keys
Parameter
Default
Range
Bus Zones Configuration
The Bus Zone Parameters menu contains parameters that enable you to
program the special parameters of a bus zone. The options are
determined according to the bus detector type:
Lunar Grade 3: A dual technology ceiling detector with a
mounting height of up to 8.6m (28ft) that incorporates Anti‐
Cloak
TM
Technology (ACT).
WatchOUT DT: A dual technology outdoor detector with signal
processing based on two Passive Infrared (PIR) channels and two
Microwave (MW) channels.
WatchOUT PIR: An outdoor detector with signal processing based
on two Passive Infrared (PIR) correlated channels
WatchIN DT Grade 3: A dual technology Grade 3 industrial
detector with signal processing based on two Passive Infrared (PIR)
channels and two Microwave (MW) channels.
iWISE QUAD Grade 2: A motion detector incorporating Quad PIR
technology
iWISE QUAD Grade 3: A motion detector incorporating Anti‐Mask
and Quad PIR technologies.