RISCO Group LightSYS 2 User Manual
Page 80

Installer Programming
Page 80
Quick Keys
Parameter
Default
Range
Fire Temporal Pattern
No
Yes/No
YES: During a fire alarm, the sirens produce a pattern of three short
bursts followed by a brief pause.
NO: During a fire alarm, the flow of sounds produced by the siren is a
pattern of two seconds ON, then two seconds OFF.
IMQ Install
No
Yes/No
YES: Causes the following parameters to function as follows:
Auto Arm Bypass: If there is an open zone during the auto arm
process, the system will be armed, and a silent alarm will be
activated (unless the open zone is closed).
A utility output defined as “Auto Arm Alarm” is activated.
A utility output defined as “Zone Loss Alarm” is activated
Guard User: If a Guard user disarms a partition, the system will be
armed automatically after the predefined time period (refer to
Guard, page 72). If there is an open zone during the arming process,
the system will be armed, and an alarm will be sounded (unless the
open zone is closed).
NO: Causes the following parameters to function as follows:
Auto Arm Bypass: If the Auto Arm programming arms the system
and there is an open zone during the auto arm, the system will
bypass the open zones and arm the system.
A utility output defined as “Auto Arm Alarm” is deactivated.
A utility output defined as “Zone Loss Alarm” is deactivated.
Guard User: If a Guard user disarms a partition, the system will be
armed automatically after the predefined time period (refer to
Guard, page 72). If there is an open zone during the arming process,
the partition will be bypassed.
Disable Incoming Calls
No
Yes/No
This parameter is used to disable all incoming calls trying to come in
through the voice channel (PSTN or GSM).
YES: Incoming calls from voice channel are disabled.
NO: Incoming calls from voice channel are enabled.
Note
Incoming data call via the GSM data channel is still enabled