RISCO Group LightSYS 2 User Manual
Page 114

Installer Programming
Page 114
Quick Keys
Parameter
Default
Range
ZZ
Anti Mask Sensitivity
Defines the sensitivity of the active IR AM: LOW HIGH
ZZ
Lens Type
Wide Angle
Defines the actual lens of the detector.
WIDE ANGLE BARRIER / LONG RANGE
ZZ
Anti‐Mask
Enable
Defines the operation of Anti Masking detection.
DISABLE Enable
ZZ
Arm/Disarm
No
Defines the operation of the LEDs and Anti masking detections while the
detector is armed.
Active IR AM and Proximity AM (Anti masking) is enabled.
LEDs behave according to the LEDs parameter definition.
YES – Active IR AM and Proximity AM (Anti masking) is disabled
LEDs are disabled.
ZZ
Prox Anti‐mask
Enable
Defines the operation of proximity anti masking detection.
DISABLE Enable
Bus Zone: WatchIN DT Grade 3
Quick Keys
Parameter
Default
Range
ZZ
LEDS
3 LEDS
Defines the LEDS operation mode.
OFF ‐ Disables the LEDS operation.
RED ONLY
‐ Only the Red LED will operate. This option is highly
recommended to avoid the possibility that a burglar will “Learn” the
detector behavior.
3 LEDS - All 3 LEDs will operate..
ZZ
Detection Sensitivity
Normal
Defines the sensitivity of the detector (MW + PIR).
LOW MEDIUM NORMAL
ACT (Anti‐Cloak™ Technology)