RISCO Group LightSYS 2 User Manual
Page 81
Installer Programming
Page 81
Quick Keys
Parameter
Default
Range
Disable Keypad When
Auto Disarm Exists
No
Yes/No
YES: When a partition is armed manually or in auto arm mode, and an
auto disarm time is defined, this parameter specifies that all the keypads
that are masked to this partition will not function and that it will be
impossible to disarm the relevant partition.
Note
The partition can be disarmed only by using the configuration software
or the auto disarm function.
NO: When a partition is armed manually or in auto arm mode, and an
auto disarm time is defined, the relevant keypads will function normally.
Buzzer Delay
No
Yes/No
YES: The keypad buzzer will be silent during the bell delay time.
NO: The keypad buzzer will be audible immediately when a system
alarm occurs.
Speaker = Buzzer
No
Yes/No
YES: The internal sounder will follow the operation of any keypad’s
buzzer.
NO: The internal sounder will follow the external sounder operation
(and not the keypad’s buzzer).
Confirmation Speaker
No
Yes/No
YES: A confirmed alarm triggers the internal sounder.
Note
A confirmed alarm actually eliminates the buzzer delay time, causing the
internal speaker to trigger immediately.
NO: The internal speaker will trigger normally (at the end of bell delay
time).
Bell Confirmation
No
Yes/No
YES: A confirmed alarm triggers the external bell.
Note
A confirmed alarm actually eliminates the bell delay time, causing the
external alarm to start immediately.
NO: The external bell will trigger normally (at the end of bell delay time).