RISCO Group LightSYS 2 User Manual
Page 92

Installer Programming
Page 92
Settings
This option allows setting the system in compliance with specific standardization, languages,
customer of panel default:
System: Settings
Quick Keys
Parameter
Default
Range
DIP 2
Enable
Enable/Disable
Used to determine whether the LightSYS2 default switch SW1‐2 is
enabled or disabled.
Enabled: When power to the main panel is switched off and then on and
SW1‐2 is in ON position , the Installer, Sub‐Installer and Grand‐Master
codes will return to the original, factory default values. In this case, after
entering the Installer Programming section, the system automatically
enters the Automatic Accessories arming setting process.
Toggle the enable/disable option with
.
Default Panel
Restores programming options to factory defaults.
The panel default option will be followed by questions regarding the
defaults of the labels and erasing wireless devices. Use
to select
your option. (See page 68)
Erase Wireless
Erase wireless devices without changing the system current
programmed parameters. Select the WL device to be erased. (Note: This
entry appears only if a wireless device is registered in the system.)
Standard
Sets the panel programming options in compliance with the selected
standard:
EN standards, page 84
PD6662:2010, page 86
CP01, page 88