RISCO Group LightSYS 2 User Manual
Page 115

Installer Programming
Page 115
Quick Keys
Parameter
Default
Range
ZZ
MW (Microwave) Range
Trimmer
Defines the microwave channel range.
MINIMUM 25% 50% 65% 85% MAXIMUM TRIMMER
(MW is defined by the trimmer setting on the PCB)
ZZ
Alarm Logic
PIR and Microwave
Determine the detector’s logic of defining an alarm.
PIR & MW (and Microwave) – An alarm is activated when both PIR
and MW channels detect an alarm (AND Logic).
PIR / MW (or Microwave) ‐ An alarm is activated when either PIR or
MW channels detect an alarm (OR Logic).
ZZ
Lens Type
Wide Angle
Defines the actual lens of the detector.
WIDE ANGLE BARRIER / LONG RANGE
ZZ
Anti‐Mask
Enable
Defines the operation of Anti Masking detection.
DISABLE ENABLE
ZZ
Arm/Disarm
No
Defines the operation of the LEDs and Anti masking detections while
the detector is armed.
Active IR AM and Proximity AM (Anti masking) is enabled.
LEDs behave according to the LEDs parameter definition.
YES – Active IR AM and Proximity AM (Anti masking) is disabled
LEDs are disabled.
ZZ
Green Line
Yes
This feature defines the activation of the microwave channel while the
system is disarmed.
NO ‐ Green Line feature is disabled. MW is constantly activated.
YES ‐ Green Line feature is enabled. This option conforms to
environmentally friendly standards by avoiding surplus emission.
ZZ
Sway
No
This option allows the recognition and immunity of swaying objects in
a known pattern.
NO ‐ Sway is disabled.
YES ‐ Sway is enabled.