RISCO Group LightSYS 2 User Manual
Page 38
Mounting and Wiring
Page 38
Connecting Backup Battery
Insert the backup battery into its place and connect the leads to the main panel battery,
PLUG7 (p. 36).
Notes:
The main panel is designed to work with an approved 12 VDC, 7 Amp‐hour
sealed lead battery as a backup for the primary power supply in time of main
power failure.
The main panel is designed with reverse polarity protection on the battery
charging circuit. However, prolonged improper connection of the battery to the
main panel will result in damage.
The battery is not supplied with the LightSYS2.
The LightSYS2 Rechargeable battery should be charged for at least 24 hours.
Battery is checked every 1 minute.
There is a risk of explosion if a battery is replaced with an incorrect type.
Dispose of used batteries according to the proper instructions.
Battery in product shall be replaced every 3‐5 years. No maintenance is needed
.
The power should remain disconnected until all connections have been made
and checked for accuracy
Use the internal jumper (Jumper 1) to configure battery discharge protection. See
page 37.