RISCO Group LightSYS 2 User Manual
Page 142

Installer Programming
Page 142
5 Communication
The Communication menu provides access to submenus and their related parameters that
enable the system to establish communication with the monitoring station, Follow Me or
Configuration Software.
The Communication menu is divided into the following sub‐menus:
Method, page 142
Monitoring Station (MS), page 153
Configuration Software, page 164
Follow Me, page 167
Method
This option allows you to configure the parameters of the communication methods
(channels) of the LightSYS, with three available communication types:
PSTN
GSM
IP
Radio (Long Range radio)
PSTN
Quick Keys
Parameter
Default
Range
PSTN
The PSTN screens contains parameters for the communication of the
LightSYS2 over the PSTN network.
Timers
Timers related to communication through the PSTN channel
PSTN Lost Delay
4 minutes
0–20 minutes
The time after which the system will regard the PSTN line as lost. This
time also specifies the delay before reporting the event into the event log
or operating a utility output that follows this event.
00 indicates no supervision of the phone line.