RISCO Group LightSYS 2 User Manual
Page 140

Installer Programming
Page 140
Quick Keys Parameter
Default
Range
Cleaner: The cleaner code is a temporary code, which is to be
immediately deleted from the system as soon as it is used to
arm. This code is typically used for maids, home attendants,
and repairmen who must enter the premises before the owner(s)
arrive. These codes are used as follows:
o
For one‐time arming in one or more partitions.
o
If first used to disarm the system, the Maid code may be
used once for subsequent arming.
User Unbypass: This user has access to all the user’s privileges
apart from bypassing zones.
Guard: This user can only disarm the system. After entering the
Guard code, the system will be disarmed for the predefined
time period (See: Guard Delay, page 72).
Duress: When coerced into disarming the system, the user can
comply with the intruder’s wishes while sending a silent duress
alarm to the central station. To do so, a special duress code must
be used, which when used, will disarm the system in the regular
manner, while simultaneously transmitting the duress alarm. In
any other situation the Duress authority level behaves the same
as the user authority level.
UO Control: Typically used to enable the operation of a device
controlled by a utility output (meaning a door and so on). These
codes are used only to operate a utility output.
Grand Master
Default: 1234.
The Grand Master Code is used by the system’s owner and is the highest Authority Level.
The owner can set/change the Grand Master Code.
Note:
The grand master code can also be changed in the user menu (by the grand master).
The Grand Master code is designated as Code 00.
The grand master, the installer and the sub‐installer can enter and change other level codes,
but they cannot see the code. The message [****] is displayed instead of the code