RISCO Group LightSYS 2 User Manual
Page 84
Installer Programming
Page 84
Quick Keys
Parameter
Default
Range
Configuration Software
(U/D) Enable
Yes
Yes/No
YES: Enables communication between the alarm company and the
LightSYS2 main panel using the configuration software. This enables
modifying an installationʹs configuration, obtaining status information,
and issuing main panel commands, all from a remote location.
NO: Disables communication, as detailed above.
Cloud Enable
No
Yes/No
YES: Enables communication between the LightSYS2 system and the
RISCO Cloud.
NO: Does not enable communication, as detailed above.
System: Controls: EN 50131
Quick Keys
Parameter
Default
Range
EN 50131
This section refers to controls that apply to EN 50131 approvals.
Authorize Installer
No
Yes/No
This option limits the installer and sub‐installer authorization to access
the programming menu.
YES: A grand master code is required to authorize the installer to enter
the programming mode for one hour.
NO: The installer does not need an authorization code.
Override Trouble
Yes
Yes/No
Specifies if the system/partition can be armed when there is a trouble in
the system.
YES: The system will arm even if there is a trouble in the system.
NO: When the user starts the arming process and there is a system‐
trouble, the user must confirm that he is aware of all troubles before
continuing with the arming process. The user needs to scroll the list of
troubles. At the end of the list the following question will appear:
« Override Trouble? » Using the
key he needs to toggle the option
to Y and press
.